The EOL range of exhaust duct fans are ideal for
bathrooms and toilet applications. These thinnest models on the market
with a very attractive design are the best solution to keeping the air
fresh and clean in your house. The range can be extended with the
electronic control systems with photocell, timer or humidity sensor
and the fans are compatible with all European and international
standards.
Technical data:
|
Voltage |
~220-230V/50Hz |
|
Consumption |
19 W |
|
Air flow |
100 m3/h |
|
Class |
II |
|
IP |
X4 |
|
Acoustic pressure |
38,5 dB (A) |
|
Revolutions |
2550 (rpm) |
|
Weight |
0,55 kg |
|
A |
130 mm |
|
B |
140 mm |
|
C |
13
mm |
|
D |
100
mm |
|
L |
88
mm |
 
The fans extended with the electronic
control systems have a mounted timer. Fan activation depends on the
control system.
E1-
photocell (pic.1) starting the fan is done by
the change in the light intensity in the area where the fan is
installed. The switches 1,2,3 are for setting the time of the fan
activity. Given lengths of time can be set by moving the switches
according to (pic.2).
The
4 switch is for setting two automatic cycles of the fan activity.
I. The switch in an upper position (ON): the
fan starts itself by switching off the light in the ventilated area
and works for the period of time set by the time-lag switches.
II. The switch in a low position (OFF): the fan
starts itself by switching on the light in the ventilated area and
works for as long as the light is on. After the light is turned off,
the fan keeps working for the length of time set by the time-lag
switch.
The 5 switch is for adjusting the system sensitivity to the lighting.
The upper position (ON) is for dark areas, while the low position
(OFF) is for partially lit areas. The system works on condition that
there is a significant change in the lighting.
|
|
E2- timer (pic.5)
the fan is activated after the light is switched on (1st version of
fan installation) or after pressing the switcher (2nd version of fan
installation) look in the (pic.3). After
turning off the light or switcher the fan works for the time allocated
by the adjustable screw.
 |
Fan models with timer, set the required
length of time for the fan to run after the fan is switched off by
first ensuring the mains power is isolated, and then with the cover of
the fan removed insert a small
screwdriver
into the aperture marked and slowly rotate clockwise or anti-clockwise
to increase or decrease the timer setting from 0 30 minutes.
E3-humidity sensor (pic.5) the fan is activated
automatically after receiving expected humidity threshold or switching
on the light or switcher connected according to the (pic.3).
The fan works until the switcher or light is on or the humidity above
the expected threshold. After turning off the light or switcher and
when the humidity is below the expected threshold the fan works for
the time allocated by the adjustable screw.
The time
interval is between 0 - 30 min. The fan has adjustable humidity knob
and the humidity threshold could be set up between 30-80%.
Please set up all required parameters before use.
The humidity sensor and adjustable knobs are situated in the
electronic PCB (pic.5). After connecting the fan with the wiring
system ~220-230V , the right knob should be turned on position 0min.
and the left one on the low humidity. This settings should activate
the fan. The fan works until the humidity threshold is reached by
turning the screw very slowly to high humidity position. When the
local humidity level is reached the fan should stop after 2 seconds.
Then the humidity knob should be turned 10o more to high humidity
position. If the fan is not activated it means that the humidity
threshold is below 30%. It is possible in
winter time when the heaters make the air inside the house very dry.
Please leave the humidity knob in position low and set up the timer
knob in expected position. The fan should be tested by blowing at the
humidity sensor from distance about 10cm.In this moment they should
start working.
|